CMP Products – CYCLONE-1 Type Cable Cleats
Technicial Specifications:
- Certificate obtained from an independent organization in accordance with IEC 61914:2009 Standard
- 124kA short circuit resistance
- Aluminum base and 316L Stainless Steel Strap
- Structure resistant to weather conditions and sunlight (UV)
- -50°C …+40°C standard operating temperature
- Fixing range for Trefoil cables 24 mm – 145 mm
- Fixing range for single cables 36 mm – 165 mm
- Fixing range for quad cables 21 mm – 124 mm
- Single bolt (M12) or double bolt (M10) fixing design
Categories: All Cable Equipment, Cable Cleats, Cable Equipment, General, Metalic Cable Cleats
Description
Additional information
Brand |
CMP |
---|
Reviews (0)
Be the first to review “CMP Products – CYCLONE-1 Type Cable Cleats” Cancel reply
About brand
Parturient ut id tellus vulputatre ac ultrlices a part ouriesnt sapien dignissim partu rient a a inter drum vehicula. Ornare metus laoreet tincidunt eros rolem tristique pretium malada.
Cras rhoncus vivamus luctus platea arcu laoreet selm. Curae est condenectus sed hac a parturient vestibulum.
Related products
BARTEC – Pressurized (Ex-p) Exproof Systems
Product Description
BARTEC offers an Ex solution to control and automate devices, machines and systems in Zones 1/21 and 2/22 in the form of pressurized containment Ex p systems.
Depending on the application, control units and switchgears that are not Exproof protected, as well as automation systems are installed in the enclosure. Modern, ready-to-use Exproof solutions – including the required ATEX or IECEx certification – are created with modular, ATEX certified pressurized enclosures from BARTEC. Pressure containment solutions are designed for a wide range of ambient temperatures in temperature classes T3 to T5
GET INFORMATION
BARTEC-FN – SFD – SFDE Series Exproof Floodlight with Halogen and High Pressure Discharge Lampfor Ex-Zone 1 – 21
Technical Specifications:
- Exproof Zone Class: Zone 1 - 21
- Exproof Protection (Gases): Ex II 2G Ex d IIB + H2 T3/T2 Gb & Ex II 2 G Ex de IIB + H2 T3/T2 Gb
- Exproof Protection (Dusts): Ex II 2D Ex tb IIIC T200°C … T240°C Db
- Protection Degree: IP66
- Ambient Temperature: -20 °C ÷ +60 °C
- Body Material: Corrosion Resistant Copper-free Aluminum
- Diffuser : Toughened Glass
- ATEX Certificate: INERIS 01 ATEX 0018
- OTHER AVAILABLE CERTIFICATES : IECEx INE 15.0003X, CEPEL 15.2363X, TC RU C-IT.GB08.B.01342, RINA: ELE18111CS_014, RMRS: 13.03516.315
BARTEC – EVAC lighting fixtures For incandescent and discharge lamps for Ex-Zone 1/2 – 21/22
Technical Specifications:
- Exproof Zone Class: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)
- Exproof Protection (Gases): II 2 G Ex d IIC T6÷T2 Gb
- Exproof Protection (Dusts): II 2 D Ex tb IIIC T85°C-T225°C Db
- Protection Degree: IP66
- Power supply (PRC): Conventional ballast 230V - 50Hz (p.f. corrected - cos ρ ≥ 0,95)
- Ambient Temperature: -60 °C ÷ +60 °C
- Body Material: Marine grade copper free aluminium (control gear & lamp body)
- ATEX Certificate: INERIS 01 ATEX 0054X
- OTHER AVAILABLE CERTIFICATES : IECEx: IECEx INE 13.0075X - INMETRO: CEPEL 14.2311X - EAC: TC RU C-IT.ГБ08.В.01342 (-60°C÷+60°C) - RINA: ELE18111CS_015 - RUSSIAN MARINE CERTIFICATE (RMRS): 13.03516.315
Explosion-safe window air conditioners AR-054
Technical data:
* Explosion Safety: II 3 G Ex ec h ic mc IIC T3 Gc
* European directives: 2014/34/EU (ATEX), 2014/30/EU (EMC) and 2009/125/EC (EcoDesign)
* Applied standards: EN 60079-0:2018, EN 60079-7:2015 / A1:2018, EN 60079-11:2012, EN 60079-18:2015 / A1:2017,
* EN 80079-36:2016 and EN 80079-37:2016
* Certification: EU Declaration of Conformity / Unit Assessment Certificate
* Supply voltage: 230 VAC
* Mains frequency: 50 Hz
* Connection: Fixed power cable 3 x 2.5 mm², 5 meters
* Ambient temperature: -20 °C to +45 °C
* Operational temperature: +18 °C to +43 °C
* Remote control: Infrared remote control supplied as standard
* Refrigerant: R32
GET INFORMATION
BARTEC-FN – AVC Series Fluorescent Exproof Lighting for Ex-Zone 1-21
Technical Specifications:
- Exproof Zone Class: Zone 1 - 21
- Exproof Protection (Gases): II 2 G Ex d e q IIC T4 Gb
- Exproof Protection (Dusts): II 2 D Ex tb IIIC T80°C Db
- Protection Degree: IP66
- Ambient Temperature: -20 °C to +60 °C
- Body Material: Glass Fiber Reinforced Polyester
- Protective Cover: UV resistant polycarbonate
- ATEX Certificate: LCIE 12 ATEX 3050X
- OTHER AVAILABLE CERTIFICATES : IECEx LCIE 12.0019X, Inmetro – CEPEL 15.2405X, EAC – TC RU C-IT.ГБ08.В.01342 (-40°C÷+60°C), Russian Marine Certificate – 13.03516.315
SCHUCH – Series e865 LED-Light Fitting for Ex-Zone 1/21
Technicial Specifications:
- Exproof Zone Class: Zone 1, 21 / Zone 2, 22
- Exproof Protection (Gases): II 2 G Ex eb mb op is q IIC T4 Gb
- Exproof Protection (Dusts): II 2 D Ex op is tb IIIC T80°C Db
- Protection Degree: IP66
- Power supply: 220-240V AC/DC, 0 or 50/60Hz
- Ambient Temperature: -30 °C to +55 °C
- Body Material: GRP
- ATEX Certificate: IBExU 16 ATEX 1008
- IECEx : IECEx IBE 16.0010
- Emergency Battery (e864 Series) Options Available!
Swedish Neutral Earth Fault Neutralization Device (GFN)
Product Description
The Ground Fault Neutralizer device is capable of fully compensating against all long-term phase-to-earth fault currents (both fundamental and harmonic). In addition, it performs this operation in a very short time. With the use of modern computers and power electronics, the fault current can be completely avoided. This is particularly useful in overhead line networks. It is also useful in industry and city center networks using cable. Because most of the cable faults start as single phase-to-ground. If the fault is not compensated properly, then multi-phase fault occurs by affecting other phases.
GET INFORMATION
BARTEC – GLL Series Lighting fixtures for high efficiency LED strip lamps
Techical Properties
Exproof Zone Class: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)
Exproof Protection (Gases): II 2G Ex db eb mb IIC T5 Gb
Exproof Protection (Dusts): II 2D Ex tb IIIC T85°C Db
Protection Degree: IP66
Power supply: 220-240 Vac electronic driver
50/60 Hz 176-280 Vdc electronic driver
Ambient Temperature: -20 °C ÷ +60 °C
Body Material: Glass fiber reinforced polyester resin self-extinguishing acc. to UL94
ATEX Certificate: INERIS 21 ATEX 0029X
IECEx : IECEx INE 21.0056X