Showing 1–12 of 14 results

CMP Products – SATURN QUAD Series Cable Cleats

Technicial Specifications:
  • Certificate obtained from an independent organization in accordance with IEC 61914 Standard
  • 152kA short circuit resistance
  • 316L Stainless Steel Body
  • Structure resistant to weather conditions and sunlight (UV)
  • -50°C …+60°C standard operating temperature
  • Fixing capacity in the cable outer diameter range of 19 mm – 71 mm
  • 18 different QUAD size options
  • Single bolt (M10) and two bolt (M10) fixing options
GET INFORMATION

CMP Products – CONQUEROR Series Cable Cleats

Technicial Specifications:
  • Certificate obtained from an independent organization in accordance with IEC 61914 Standard
  • 170kA short circuit resistance
  • 316L Stainless Steel Body
  • Structure resistant to weather conditions and sunlight (UV)
  • -50°C …+60°C standard operating temperature
  • Wider cable tightening range thanks to adjustable hinge structure
  • Fixing capacity in the cable outer diameter range of 23 mm – 130 mm
  • 15 different Trefoil Structure size options
  • Single bolt (M12) and two bolt (M10) fixing options
GET INFORMATION

CMP Products – HURON Series Cable Cleats

Technicial Specifications:
  • Certificate obtained from an independent organization in accordance with IEC 61914 Standard
  • 84kA short circuit resistance
  • 3mm Thickness 5000 Series Aluminum Body
  • Structure resistant to weather conditions and sunlight (UV)
  • -50°C …+60°C standard operating temperature
  • Fixing capacity in the cable outer diameter range of 19 mm – 128 mm
  • 23 different Trefoil Structure size options
  • Single bolt (M10) and two bolt (M10) fixing options
GET INFORMATION

CMP Products – PATRIOT Series Cable Cleats

Technicial Specifications:
  • Certificate obtained from an independent organization in accordance with IEC 61914 Standard
  • 135kA short circuit resistance
  • 316L Stainless Steel Body
  • Structure resistant to weather conditions and sunlight (UV)
  • -50°C …+60°C standard operating temperature
  • Fixing capacity in the cable outer diameter range of 17 mm – 128 mm
  • 24 different Trefoil Structure size options
  • Single bolt (M10) and two bolt (M10) fixing options
GET INFORMATION

CMP Products – RELIANCE Series Cable Cleats

Technicial Specifications:
  • Certificate obtained from an independent organization in accordance with IEC 61914 Standard
  • 106kA short circuit resistance
  • 3mm Thickness 5000 Series Aluminum Body
  • Structure resistant to weather conditions and sunlight (UV)
  • -50°C …+60°C standard operating temperature
  • Fixing capacity in the cable outer diameter range of 19 mm – 128 mm
  • 24 different Trefoil Structure size options
  • Single bolt (M10) and two bolt (M10) fixing options
GET INFORMATION

SOVEREIGN Series Cable Cleats

FEATURES
  • Third party certification to IEC 61914
  • 316L stainless steel
  • 17 - 128mm in 24 sizes for trefoil formation /application
  • Short circuit rating of 190kA peak fault
  • Operating temperature -50°C to +60°C
  • Liners are classified as Low Smoke & Fume (LSF),
  • Zero Halogen (LS0H) and Phosphorus Free
  • Combined single (M12) and two bolt (M10) fixing design
GET INFORMATION

CMP Products – CYCLONE-3 Series Cable Cleats

Technicial Specifications:
  • Certificate obtained from an independent organization in accordance with IEC 61914:2009 Standard
  • 180kA short circuit resistance
  • 316L Stainless Steel Body
  • Structure resistant to weather conditions and sunlight (UV)
  • -50°C …+40°C standard operating temperature
  • Fixing range for Trefoil cables 24 mm – 145 mm
  • Fixing range for single cables 36 mm – 165 mm
  • Fixing range for quad cables 21 mm – 124 mm
  • Single bolt (M12) or double bolt (M10) fixing design
GET INFORMATION

CMP Products – SAPPHIRE Series Single Cable Cleats

Technicial Specifications:
  • Certificate obtained from an independent organization in accordance with IEC 61914:2009 Standard
  • 316L Stainless Steel Body
  • Structure resistant to weather conditions and sunlight (UV)
  • 105kA short circuit resistance
  • -50°C…+60°C standard operating temperature
  • Fixing capacity in the cable outer diameter range of 19 mm – 165 mm
  • 14 different size options
  • Single bolt (M12) or double bolt (M10) fixing design
GET INFORMATION

CMP Products – CYCLONE-1 Type Cable Cleats

Technicial Specifications:
  • Certificate obtained from an independent organization in accordance with IEC 61914:2009 Standard
  • 124kA short circuit resistance
  • Aluminum base and 316L Stainless Steel Strap
  • Structure resistant to weather conditions and sunlight (UV)
  • -50°C …+40°C standard operating temperature
  • Fixing range for Trefoil cables 24 mm – 145 mm
  • Fixing range for single cables 36 mm – 165 mm
  • Fixing range for quad cables 21 mm – 124 mm
  • Single bolt (M12) or double bolt (M10) fixing design
GET INFORMATION

CMP Products – CYCLONE-2 Type Cable Cleats

Technicial Specifications:
  • Certificate obtained from an independent organization in accordance with IEC 61914:2009 Standard
  • 151kA short circuit resistance
  • 316L Stainless Steel Body
  • Structure resistant to weather conditions and sunlight (UV)
  • -50°C …+40°C standard operating temperature
  • Fixing range for Trefoil cables 24 mm – 145 mm
  • Fixing range for single cables 36 mm – 165 mm
  • Fixing range for quad cables 21 mm – 124 mm
  • Single bolt (M12) or double bolt (M10) fixing design
GET INFORMATION

CMP Products – VALIANT Series Single Cable Cleats

Technicial Specifications:
  • Certificate obtained from an independent organization in accordance with IEC 61914:2009 Standard
  • Body made of aluminum casting material
  • Structure resistant to weather conditions and sunlight (UV)
  • -60°C…+150°C standard operating temperature
  • Fixing capacity in the cable outer diameter range of 10 mm – 71 mm
  • 12 different size options
  • Single bolt fixing design
GET INFORMATION

ZENITH Series Cable Cleats

TECHNICAL DATA & CLASSIFICATION TYPE: 6.1.1 Metallic 2BCAL - Two Bolt Aluminium Cable Cleat DESIGN SPECIFICATION: IEC 61914 TEMPERATURE FOR PERMANENT APPLICATION: -60°C to 150°C IEC 61914 clause / part 6.2 NEEDLE FLAME TEST: Pass IEC 61914 clause 10.0, 10.1, IEC 60695-11-5 LATERAL LOAD TEST: 18kN - 32kN, IEC 61914 clause 9.3 AXIAL LOAD TEST: 8kN, IEC 61914 clause 9.4 IMPACT RESISTANCE: Pass - Very heavy IEC 61914 clause 6.3, 6.3.5, 9.2 MATERIAL: High pressure die cast aluminium MATERIAL COLOUR: Silver / grey GET INFORMATION