CMP Products – Cable Gland Locknuts
Technicial Specifications:
- Accessory Material: Solid Brass – Nickel Plated Brass – Aluminum – Stainless Steel
- LN* coded products are designed for standard applications
- HLN* coded products are designed for heavy duty work.
- Nickel plated brass code: **LN5
- Brass code: **LN
- Stainless steel code: **LN4
Categories: All Cable Equipment, Cable Equipment, General, Gland Accessories
Description
Additional information
Brand |
CMP |
---|
Reviews (0)
Be the first to review “CMP Products – Cable Gland Locknuts” Cancel reply
About brand
Parturient ut id tellus vulputatre ac ultrlices a part ouriesnt sapien dignissim partu rient a a inter drum vehicula. Ornare metus laoreet tincidunt eros rolem tristique pretium malada.
Cras rhoncus vivamus luctus platea arcu laoreet selm. Curae est condenectus sed hac a parturient vestibulum.
Related products
SCHUCH – Series e865 LED-Light Fitting for Ex-Zone 1/21
Technicial Specifications:
- Exproof Zone Class: Zone 1, 21 / Zone 2, 22
- Exproof Protection (Gases): II 2 G Ex eb mb op is q IIC T4 Gb
- Exproof Protection (Dusts): II 2 D Ex op is tb IIIC T80°C Db
- Protection Degree: IP66
- Power supply: 220-240V AC/DC, 0 or 50/60Hz
- Ambient Temperature: -30 °C to +55 °C
- Body Material: GRP
- ATEX Certificate: IBExU 16 ATEX 1008
- IECEx : IECEx IBE 16.0010
- Emergency Battery (e864 Series) Options Available!
RAYTEC LED – SPARTAN SPX Exproof Projector for Ex-Zone 1- 21
Technical Specifications:
- Exproof Zone Class: hazardous areas - Zone 1 (Gases) - Zone 21 (Dusts)
- Exproof Protection (Gases): Ex II 2 G Ex e mb op is IIC T4 Gb
- Exproof Protection (Dusts): Ex II 2 D Ex tb op is IIIC T82°C Db
- Protection Degree: IP66 / IP67
- Power supply: 110-254V 50/60 Hz AC
- Low voltage: 18-48V AC and 18-69V DC
- Extra low voltage: 12V AC/DC
- Ambient Temperature: -50 °C ÷ +55 °C (The low temperature is -20°C for the battery-powered Emergency features.)
- Body Material: Corrosion Resistant Aluminum, epoxy powder coated
- ATEX Certificate: CML13ATEX3007
- IECEx Certificate: IEC Ex CML 14.0001
- OTHER AVAILABLE CERTIFICATES : UL/CSA, including C1D2; ABS Cert. # 15-LD1364539-1-PD
SCHUCH – e8820 Series LED Exproof Explosion-protected LED floodlight (Zone 1, 21 Zone 2, 22)
Technicial Specifications:
Exproof Zone Class: Zone 1, 21 / Zone 2, 22
Exproof Protection (Gas): II 2 G Ex eb mb q IIC T4 Gb
Exproof Protection (Dust): II 2 D Ex tb IIIC T100 °C Db
IP rating: IP66
Rated voltage: 220 - 240 V, 0 Hz, 50/60 Hz
Tₐ: -30 °C to +55 °C
Housing Material: Die-cast aluminium
ATEX: IBExU 20 ATEX 1117
IECEx : IECEx IBE 20.0028
GET INFORMATION
BARTEC – Pressurized (Ex-p) Exproof Systems
Product Description
BARTEC offers an Ex solution to control and automate devices, machines and systems in Zones 1/21 and 2/22 in the form of pressurized containment Ex p systems.
Depending on the application, control units and switchgears that are not Exproof protected, as well as automation systems are installed in the enclosure. Modern, ready-to-use Exproof solutions – including the required ATEX or IECEx certification – are created with modular, ATEX certified pressurized enclosures from BARTEC. Pressure containment solutions are designed for a wide range of ambient temperatures in temperature classes T3 to T5
GET INFORMATION
ZENITH Series Cable Cleats
TECHNICAL DATA & CLASSIFICATION
TYPE: 6.1.1 Metallic 2BCAL - Two Bolt Aluminium Cable Cleat
DESIGN SPECIFICATION: IEC 61914
TEMPERATURE FOR PERMANENT APPLICATION: -60°C to 150°C
IEC 61914 clause / part 6.2
NEEDLE FLAME TEST:
Pass
IEC 61914 clause
10.0, 10.1, IEC 60695-11-5
LATERAL LOAD TEST: 18kN - 32kN, IEC 61914 clause 9.3
AXIAL LOAD TEST: 8kN, IEC 61914 clause 9.4
IMPACT RESISTANCE: Pass - Very heavy
IEC 61914 clause 6.3, 6.3.5, 9.2
MATERIAL: High pressure die cast aluminium
MATERIAL COLOUR: Silver / grey
GET INFORMATION
BARTEC – Ex-d Protected Exproof Distribution Board
Technical Specifications:
- Exproof Zone Class: hazardous areas - Zone 1 / 21 (Gases) - Zone 2 / 22 (Dusts)
- Exproof Protection (Gases): II 2G Ex d IIC T6..T3 Gb
- Exproof Protection (Dusts): II 2D Ex tb IIIC T85°C..T150°C Db
- Protection Degree: IP65 / IP66
- Power supply (PRC): Conventional ballast 230V - 50Hz (p.f. corrected - cos ρ ≥ 0,95)
- Ambient Temperature: -20 °C ÷ +40 °C (-55°C ÷ +55°C)
- Body Material: Glass-Fiber Reinforced Polyester, Steel Sheet, Stainless Steel
- ATEX Certificate: DEKRA I3ATEXO2O9
- OTHER AVAILABLE CERTIFICATES : IECEx, CU TR
BARTEC-FN – AVC Series Fluorescent Exproof Lighting for Ex-Zone 1-21
Technical Specifications:
- Exproof Zone Class: Zone 1 - 21
- Exproof Protection (Gases): II 2 G Ex d e q IIC T4 Gb
- Exproof Protection (Dusts): II 2 D Ex tb IIIC T80°C Db
- Protection Degree: IP66
- Ambient Temperature: -20 °C to +60 °C
- Body Material: Glass Fiber Reinforced Polyester
- Protective Cover: UV resistant polycarbonate
- ATEX Certificate: LCIE 12 ATEX 3050X
- OTHER AVAILABLE CERTIFICATES : IECEx LCIE 12.0019X, Inmetro – CEPEL 15.2405X, EAC – TC RU C-IT.ГБ08.В.01342 (-40°C÷+60°C), Russian Marine Certificate – 13.03516.315
BARTEC – Ex-e Medium Voltage Terminal Boxes (6kV to 10kV) for Ex-Zone 1-21
Technicial Specifications:
- Exproof Zone Class: Zone 1, 21
- Exproof Protection: Ex II 2G Ex e IIC T6/T5 Gb / Ex II 2D Ex tb IIIC T80 °C/T95 °C Db
- Protection Degree: IP66
- Ambient Temperature: -20°C ÷ +40°C (-55°C ÷ +55°C in certain cases)
- Body Material: Polyester or Stainless Steel
- ATEX Certificate: IBExU 13 ATEX 1001