Products

RAYTEC – SPARTAN High Power Ex-Proof Floodlight

TECHNICAL SPECIFICATIONS Ex-Proof Zone Classification: Zone 2, 22 Ex-Proof Protection (Gas): Ex ec nR IIC T4 Gc Ex-Proof Protection (Dust): Ex tc IIIC T104°C Dc Ingress Protection: IP66 Operating Voltage: 110–277VAC 50/60Hz Operating Ambient Temperature: -50°C to +50°C ATEX Certificate: CML 17ATEX 4149 Other Certifications: IECEx CML 17.0074 GET INFORMATION...

SCHUCH – ExeLED 2 nD866 LED Ex-proof Linear Luminaire

Technical Specifications: Ex-proof Zone Classification: Zone 2, 22 Explosion Protection (Gas): II 3G Ex ec IIC T4 Gc Explosion Protection (Dust): II 3D Ex tc IIIC T80°C Dc Ingress Protection: IP66 Operating Voltage: 220–240V AC/DC, 0 or 50/60Hz, with surge, overload, and short-circuit protection Ambient Operating Temperature: -30°C to +40°C ATEX Certificate: IBExU 16 ATEX B006 Other Certifications: IECEx IBE 15.0015 GET INFORMATION...

SCHUCH – nD8611 Compact LED Ex-proof Emergency Exit Luminaire

Technical Specifications: Ex-proof Zone Classification: Zone 2, 22 Explosion Protection (Gas): II 3G Ex nR IIC T4 Gc Explosion Protection (Dust): II 3D Ex tc IIIC T80°C Dc Ingress Protection: IP65 Operating Voltage: 220–240V, 50/60 Hz Ambient Operating Temperature: -20°C to +40°C GET INFORMATION...

SCHUCH – e821 LED Ex-proof Linear Luminaire

Technical Specifications: Ex-proof Zone Classification: Zone 1, 21 / Zone 2, 22 Explosion Protection (Gas): II 2G Ex eb mb q IIC T4 Gb Explosion Protection (Dust): II 2D Ex tb IIIC T80°C Db Ingress Protection: IP65 Operating Voltage: 220–240V AC/DC, 0 or 50/60Hz, with overload, overvoltage, and short-circuit protection Ambient Operating Temperature: -30°C to +55°C ATEX Certificate: IBExU 20 ATEX 1017 Other Certifications: IECEx IBE 19.0032 GET INFORMATION...

SCHUCH – ExSPECT e9310 LED Ex-proof Hand Lamp

Technical Specifications: Ex-proof Zone Classification: Zone 1, 21 / Zone 2, 22 Explosion Protection (Gas): II 2G Ex eb mb op is IIC T4 Gb Explosion Protection (Dust): II 2D Ex op is tb IIIC T80°C Db Ingress Protection: IP66 Operating Voltage: 220–240V AC/DC, 0 or 50/60Hz Ambient Operating Temperature: -25°C to +40°C ATEX Certificate: IBExU 19 ATEX 1134 Other Certifications: IECEx IBE 19.0028 GET INFORMATION...

SCHUCH – ExGLOBE E9312 LED Ex-proof Luminaire

Technical Specifications: Ex-proof Zone Classification: Zone 1, 21 / Zone 2, 22 Explosion Protection (Gas): II 2G Ex eb mb IIC T4 Gb Explosion Protection (Dust): II 2D Ex tb IIIC T80°C Db Ingress Protection: IP66 Operating Voltage: 220–240V AC/DC, 0 or 50/60Hz Ambient Operating Temperature: -25°C to +40°C ATEX Certificate: IBExU 20 ATEX 1092 IECEx Certificate: IECEx IBE 20.0013 GET INFORMATION...

BARTEC – Line bushings with terminals

Zone Class : Zone 1, 21 Explosion-proof Protection : Ex II 2G Ex db eb IIC Gb Ex I M2 Ex db eb I Mb IP Rating : IP66 Operating Temperature : -60 °C ≤ Ta ≤ +110 °C ATEX Certificate : EPS 14 ATEX 1644 U Other Certificates : IECEx EPS 13.0045 U...

RAYTEC – Spartan Mid Power Flood

ATEX Rating ATEX, UKEX and IEC Ex rated for Gas and Dust Hazardous Area Rating Zone 1 (Gas), Zone 21(Dust) Certificates CML21ATEX3317 & IEC Ex CML21.0037 or CML21UKEX3319 Gas II 2 G D Ex eb mb IIC T4 Gb Ta= -40°C to +60°C (-20°C to +50°C emergency variants) Dust Ex tb IIIC T90°C Db Ta= -40°C to +60°C (-20°C to +50°C emergency variants) ABS Certificate # 23-2432337-PDA...

BARTEC – EXgate™215

Zone Class : Zone 1, 21 Explosion-proof Protection : ­­­­­­II 2 G Ex db eb IIC T6/T5/T4 Gb II 2 D Ex tb IIIC T70°C/80°C/95°C/100°C IP Rating : IP66 Operating Temperature : -20°C ≤ Tamb ≤ +72°C ATEX Certificate : DNV-2004-OSL-ATEX-0115...

BARTEC – ETH9 – EFST acoustic Signaller

Zone Class : Zone 1, 21 Explosion-proof Protection : Ex II 2 G Ex d IIC T6 Gb Ex II 2 D Ex tb IIIC T85 °C Db IP Rating : IP66 Operating Temperature : -60 °C to +60 °C ATEX Certificate : INERIS 15 ATEX 0012X Other Certificates : IECEx INE 15_0013X...