Materials and Coating
Sensor: Die-cast aluminum (AS 13) housing (EN AC-44300), silver-gray powder-coated, available in any RAL color upon request.
Standard corrosion class C5 according to ISO 9223:2012.
Decorative arched column (France): Galvanized steel painted in light gray.
Installation and Mounting
To be mounted on top of a pole at a height of 3 to 4 m, pole top size 100 mm, external connection piece (with luminaire): 60 mm x 80 mm. Compatible with all LED luminaires with a connection height <85 mm (position of fixing screws).
Pre-wired with 4 m CSA 4x1mm² cable, connection at the bottom of the pole.
In a new master/slave installation (pilot line or RF), it is recommended to use two pole heights to maintain the same level between lighting points. The slave pole should be 400 mm higher than the master.
For existing installations, note that the master unit must be 400 mm higher than the secondary units; this may be noticeable when spacing is less than 20 m. Coordinated decorative poles are available as standard.
Specification
For status indication:
An outdoor PIR device will be post-top mounted on a 3 or 4 m pole with a 60 mm spigot. It can be oriented in any direction together with IP66 LED luminaires programmed in corridor mode, detecting pedestrians, cyclists, or slow-moving vehicles (under 30 km/h) at a distance of 4 to 20 m.
Thorn MovU PIR Post Top.