{"id":10528,"date":"2024-05-01T17:02:53","date_gmt":"2024-05-01T14:02:53","guid":{"rendered":"https:\/\/ethosenerji.com\/en\/?post_type=product&#038;p=10528"},"modified":"2024-05-01T17:22:23","modified_gmt":"2024-05-01T14:22:23","slug":"bartec-ejb-enclosure","status":"publish","type":"product","link":"https:\/\/ethosenerji.com\/en\/product\/bartec-ejb-enclosure\/","title":{"rendered":"BARTEC &#8211; EJB enclosure"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column][vc_column_text woodmart_inline=&#8221;no&#8221; text_larger=&#8221;no&#8221;]<\/p>\n<h2 class=\"product-show__description-header\">Description<\/h2>\n<p>Our flameproof enclosure EJB or BARTEC B series is designed to be installed in industrial plants, where potential hazardous atmospheres occur.<br \/>\nThese areas are either classified as zone 1 and 2 or as zone 21 and 22.<br \/>\nThe flameproof enclosure EJB is designed to contain regular industrial electrical components or equipment on the mounting plate like fuses, transformers, circuit breakers, relays, PLC etc.. This enclosure can fully integrated in the hazardous area as control\u00a0 or distribution panel. Our flameproof enclosure EJB for hazardous areas is globally certified for use in worldwide applications and plants.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Technical Data<\/strong><\/p>\n<table class=\"table caption-top\">\n<tbody>\n<tr>\n<th scope=\"row\">Protection class<\/th>\n<td>IP 66 (IEC\/EN 60529)<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Material<\/th>\n<td>Enclosure material:Copper free aluminium alloy ( 0.1% copper)<br \/>\nSurface treatment: External powder type painted RAL9006<br \/>\nInternal anti-condense painting RAL2004 (optional)<br \/>\nEnclosure lid: Bolts in stainless steel AISI304 (A2)<br \/>\nInternal mounting plate : Aluminium<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Weight<\/th>\n<td>see data sheet<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Dimensions<\/th>\n<td>see data sheet<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Accessories<\/th>\n<td>O-Ring silicon rubber gasket (optional)<br \/>\nGlass round\/square shape window (optional)<br \/>\nDrain and breather valves (optional)<br \/>\nHinged lid : On long side (standard)<br \/>\nOn shorth side (optional)<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Quantity of cable entries<\/th>\n<td>see data sheet<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Voltage<\/th>\n<td>Max. rated voltage : 13kV (AC) \/ 750V (DC)<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Current<\/th>\n<td>Max. rated current : 2000A<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Imapct test<\/th>\n<td>7 Joule for metallic parts of enclosure<br \/>\n2 Joule for tempered glass windows<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 class=\"h5 product-show__marking-header\">Marking<\/h2>\n<p>ATEX:<br \/>\n(Ex II 2 G) Ex db IIA or IIB or IIB+H2 T6\u2026T3<br \/>\n(Ex II 2 G) Ex db [ia\/ib IIA or IIB or IIC Ga] IIA or IIB or IIB+H2 T6<br \/>\n(Ex II 2 D) Ex tb IIIC T85\u00b0C\u2026T200\u00b0C<br \/>\n(Ex II 2 D) Ex tb [ia Da\/ib] IIIC T85\u00b0C<\/p>\n<p>IECEx:<br \/>\nEx db IIA or IIB or IIB+H2 T6 or T5 or T4 or T3 Gb<br \/>\nEx db [ia IIA or IIB or IIC Ga] IIA or IIB or IIB+H2 T6 or T5 or T4 or T3 Gb<br \/>\nEx db [ib IIA or IIB or IIC] IIA or IIB or IIB+H2 T6 or T5 or T4 or T3 Gb<br \/>\nEx tb III C T85\u00b0C or T100\u00b0C or T135\u00b0C or T200\u00b0C Db<br \/>\nEx tb [ia Da] IIIC T85\u00b0C or T100\u00b0C or T135\u00b0C or T200\u00b0C Db<br \/>\nEx tb [ib] IIIC T85\u00b0C or T100\u00b0C or T135\u00b0C or T200\u00b0C Db<\/p>\n<h2><\/h2>\n<h2 class=\"h5 product-show__temperature-description-header\">Ambient Temperature<\/h2>\n<p>-60 \u00b0C to +80 \u00b0C (standard)[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/2&#8243;]\n\t\t<div id=\"wd-64df2a6cb6e90\" class=\"title-wrapper wd-wpb wd-set-mb reset-last-child  wd-rs-64df2a6cb6e90 wd-title-color-default wd-title-style-default text-center  wd-underline-colored\">\n\t\t\t\n\t\t\t<div class=\"liner-continer\">\n\t\t\t\t<h4 class=\"woodmart-title-container title  wd-font-weight- wd-fontsize-m\" >TECHNICAL DOCUMENT<\/h4>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\n\t\t\t\n\t\t\t\n\t\t<\/div>\n\t\t\n\t\t<div id=\"wd-66324c7b2e286\" class=\" wd-rs-66324c7b2e286  wd-button-wrapper text-center\"><a href=\"https:\/\/ethosenerji.com\/en\/wp-content\/uploads\/2024\/05\/41_ESS_413605_ds_EJB_EN_MAK-1.pdf\" title=\"\" target=\"_blank\" class=\"btn btn-style-default btn-shape-rectangle btn-size-default btn-icon-pos-left\">BARTEC - EJB enclosure<span class=\"wd-btn-icon\"><span class=\"wd-icon fas fa-file-pdf\"><\/span><\/span><\/a><\/div>[\/vc_column][vc_column width=&#8221;1\/2&#8243;]\n\t\t<div id=\"wd-64df24a41e9b7\" class=\"title-wrapper wd-wpb wd-set-mb reset-last-child  wd-rs-64df24a41e9b7 wd-title-color-default wd-title-style-default text-center  wd-underline-colored\">\n\t\t\t\n\t\t\t<div class=\"liner-continer\">\n\t\t\t\t<h4 class=\"woodmart-title-container title  wd-font-weight- wd-fontsize-m\" >CERTIFICATES<\/h4>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\n\t\t\t\n\t\t\t\n\t\t<\/div>\n\t\t\n\t\t<div id=\"wd-66324c838ece1\" class=\" wd-rs-66324c838ece1  wd-button-wrapper text-center\"><a href=\"https:\/\/ethosenerji.com\/en\/wp-content\/uploads\/2024\/05\/Declaration_conformity_DC14-223_R6_EJB-1.pdf\" title=\"\" target=\"_blank\" style=\"--btn-color:#fff;--btn-color-hover:#fff;\" class=\"btn btn-style-default btn-shape-rectangle btn-size-default btn-icon-pos-left\">BARTEC - EJB enclosure<span class=\"wd-btn-icon\"><span class=\"wd-icon fas fa-file-pdf\"><\/span><\/span><\/a><\/div>[\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Ex d IIB+H2 aluminium enclosure for zone 1\/2 &#8211; 21\/22<\/p>\n<h2 class=\"h5 product-show__benefits-header\">Benefits<\/h2>\n<ul>\n<li>Group IIB+H2<\/li>\n<li>Aluminium alloy<\/li>\n<li>IP 66<\/li>\n<li>Available with glass window on the cover for viewing internal instruments.<\/li>\n<\/ul>\n","protected":false},"featured_media":10529,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[81,114,112,126,115],"product_tag":[],"class_list":{"0":"post-10528","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ex-e-protected-exproof-terminal-box","7":"product_cat-exproof-all-products","8":"product_cat-exproof-products","9":"product_cat-exproof-terminal-box-and-exproof-junction-box","10":"product_cat-general","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/ethosenerji.com\/en\/wp-json\/wp\/v2\/product\/10528","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ethosenerji.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ethosenerji.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/ethosenerji.com\/en\/wp-json\/wp\/v2\/comments?post=10528"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ethosenerji.com\/en\/wp-json\/wp\/v2\/media\/10529"}],"wp:attachment":[{"href":"https:\/\/ethosenerji.com\/en\/wp-json\/wp\/v2\/media?parent=10528"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/ethosenerji.com\/en\/wp-json\/wp\/v2\/product_brand?post=10528"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/ethosenerji.com\/en\/wp-json\/wp\/v2\/product_cat?post=10528"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/ethosenerji.com\/en\/wp-json\/wp\/v2\/product_tag?post=10528"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}